CAUTION
Do not use round cord for lacing or tying coaxial cable or bundles that contain
coaxial cable. Use only the approved military specification tape to lace or tie coaxial
cables or bundles containing coaxial cables.
Q47. What is the purpose of a lacing shuttle?
Q48. When should wires be twisted prior to lacing?
Q49. What precautions should you take when tying bundles containing coaxial cables?
2.3.10.1 Single Lace
Single lace can be started with a
square knot and at least two marling
hitches drawn tightly. Details of the
square knot and marling hitch are
shown in figure 2-41. Do not confuse
the marling hitch with a half hitch. In
the marling hitch, the end is passed
over and under the strand, as shown
in view A of the figure. After
forming the marling hitches, draw
them tightly against the square knot,
as shown in view B. The lace
consists of a series of marling hitches
evenly spaced at 1/2-inch to 1-inch
intervals along the length of the
group of conductors, as shown in
view C of the figure.
Figure 2-41 Applying single lace